Correct. Each axis measures how much of gravityās 1 g lies along it, and with the board flat, all of it lands on z, whose upward direction reads positive.
Approximately 0 on all three axes, because the board is not moving.
Gravity is an acceleration, and each axis measures how much of it lies along that axis. Flat on the table, component side up, z reads approximately +1000 mg.
Approximately +1000 on every axis.
Each axis measures only the part of gravity that lies along that axis. Flat on the table, gravity lies along z alone, so x and y read near zero.
Approximately ā1000 on z.
The sign is worth getting right: ā1000 mg on z is what the board reads flipped over, with z pointing down. Component side up, z points up and reads approximately +1000 mg.
Correct. That is the typical value; the tableās Min and Max columns allow ±80 mg. It is why a flat board reads close to, but rarely exactly, +1000 mg on z.
±80 mg
±80 mg is the tableās Min and Max bound, the worst case. The typical column says ±40 mg.
±4 mg
4 mg is the sensitivity per digit in normal mode at ±2 g, a different row of the same table. The typical zero-g offset is ±40 mg.
0 mg; a stationary axis reads exactly its share of gravity.
A real sensor carries a small constant offset; the datasheet says ±40 mg is typical. That is why the reading is āapproximatelyā +1000 mg, not exactly.