It rises, and it stays high for as long as the cell is covered.
Correct. With less light, fewer electrons are freed from the lattice, so fewer are available to conduct and the resistance rises. It stays high until light returns.
It falls, because the cell is no longer being driven by light.
Light is what frees the electrons that conduct. Less light means fewer free electrons, which is a higher resistance, not a lower one.
It rises briefly and then returns to its lit value.
The resistance depends on the light falling on the cell at the time. It does not return to a previous value while the cell stays covered.
It does not change; resistance is a fixed property of the part.
For a plain resistor that is true. A photocell is a resistor whose resistance depends on the light on its face, which is what makes it a sensor.
Two photocells of the same part number, from the same bag, are placed side by side under the same lamp, and their resistances differ by a third. What is the most likely explanation?
Nothing is wrong: photocells vary from one unit to the next by that much, and the datasheet gives ranges rather than one value.
Correct. The Adafruit guide puts the variation at 50% or higher, even within a batch, and the datasheet says the part is available in a wide range of resistance values. A tracker built from two such cells has to allow for the difference between them.
One of the two cells is defective.
A difference of a third is within the normal variation for these parts. A defective cell would read open, or would not change with light at all.
The cells need a few minutes under the lamp before they agree.
The rise and fall times on the datasheet are tens of milliseconds, so both cells respond in tens of milliseconds, not minutes. The difference is between the cells themselves.
The multimeter is inaccurate at these resistances.
A multimeter reads resistances in the kilohm range to within a percent or so. The difference is in the parts.
Suppose the divider is wired the other way around from Figure 14.1.2: the fixed resistor from \(V_{cc}\) to the node, and the photocell from the node to ground. When the light on the photocell gets brighter, what happens to \(V_M\text{?}\)
Correct. With the photocell at the bottom, the formula becomes \(V_M = V_{cc} \cdot R_\text{sens}/(R_M +
R_\text{sens})\text{:}\) the photocell’s resistance is now in the numerator, and as it falls the fraction falls.
Correct. A strain gage’s resistance changes by a very small fraction of its value, too small a change for a divider and our ADC to resolve, so strain gages and the load cells built from them require more complex electronics.
A thermistor.
A thermistor’s resistance changes a great deal with temperature, and a divider reads it directly.
A force-sensing resistor.
A force-sensing resistor changes its resistance by a large factor with force, and a divider reads it directly.
A potentiometer.
A potentiometer is its own divider, which is how it gave the ADC a voltage in the ADC chapter.