Skip to main content

Subsection 12.3.5 Part 5: Settings for Basic Accelerometer Operation

We now know how to read the data out of the sensor. What we have not done yet is tell the sensor how to run. The accelerometer has six control registers, all reachable over I2C. Only two of them matter for us. The rest are about features we leave at their defaults.
Register What it governs
CTRL_REG1_A Data rate, power mode (the LPen bit, low-power enable), axis selection. Ours to set.
CTRL_REG2_A High-pass filter configuration (§8.7); bypassed by default.
CTRL_REG3_A Interrupt selection (none used; off by default).
CTRL_REG4_A Full-scale range (±2, ±4, ±8, ±16 g) and the HR bit (high resolution); together with LPen in CTRL_REG1_A it picks the resolution mode. Ours to set.
CTRL_REG5_A Interrupt configuration (unused; defaults).
CTRL_REG6_A Interrupt configuration (unused; defaults).
Everything we did today assumed the ±2 g range; the sensitivity derivation used normal mode, and the worked conversions used low-power. CTRL_REG1_A and CTRL_REG4_A are where both choices actually get made, and working out their settings from the LSM303AGR datasheet is part of tonight’s homework (Section 12.4).