Subsection 10.4.3 The Protocol: START and STOP Conditions

With the exception of the START and STOP conditions, SDA is allowed to change only while SCL is LOW. That is when the receiver is not sampling it; while SCL is HIGH, SDA holds still and is read. The protocol then takes the one thing that rule forbids and uses it to mark the edges of a transaction, which is why a START can never be mistaken for data.
A START condition is SDA going from HIGH to LOW while SCL is HIGH. It cannot occur during normal data transfer, so every device on the bus recognizes it immediately: a new transaction is beginning.
A STOP condition is SDA going from LOW to HIGH while SCL is HIGH. Also impossible as a data bit, it means the transaction is over and the bus is free.
Both are in Figure 10.1.12. The SDA transitions at the START and STOP markers happen while SCL is HIGH; every other SDA edge in the diagram happens while SCL is LOW. That contrast is what lets a device tell the two apart.